Print Back
Standard Features:
  • Built in accordance with A.S.M.E. Miniature Boiler Code
  • A.S.M.E. CSD-1 Compliant
  • UL Listed and labeled under UL 834
  • Dual Pressure Controls (UL 353)
  • High Pressure Safety Reset. (UL 353)
  • Low Level Cut-Off (LLCO) (UL 353)
  • 100 psi Safety Relief Valve (A.S.M.E. Section I - V-Stamp)
Multiple Accessories Available
Unit of Measure

Specifications

Brands

N/A Electro-Steam™

Electrical Power

N/A 15 kW
Alternating Current (AC) Voltage1 N/A 208 V230 V380 V415 V440 V480 V600 V
Phase2 N/A 3 Ø

Frequency

N/A 50 Hz60 Hz

Boiler Horse Power

N/A 1.5 bhp
Steam Capacity3 N/A 51.75 lb/hr23.47 kg/hr
Water Consumption4 N/A 6.20 gal/hr23.47 L/hr
Gross British Thermal Units (BTU) Output5 N/A 50,213 Btu/hr

Maximum Boiler Pressure

N/A 100 psi

Operating Pressure (Factory Set at 85 Pound per Square Inch (psi))

N/A 0 to 85 psi

Maximum Boiler Capacity

N/A 6 gal

Boiler Fill Capacity

N/A 4.2 gal
Boiler Material 6 N/A Carbon Steel

Cabinet Material

N/A 304 Stainless Steel
Plumbing Material7 N/A Brass Carbon Steel (Schedule 40)

Industry Standards

N/A American Society of Mechanical Engineers (ASME) - Boiler and Pressure Vessel Code American Society of Mechanical Engineers (ASME) - CSD-1 Canadian Underwriters Laboratories (cUL) Underwriters Laboratories (UL)

Amperage

Amperage at 208 Volt (V) Alternating Current (AC) Voltage (3Ø Phase)

N/A 41.6 A

Amperage at 240 Volt (V) Alternating Current (AC) Voltage (3Ø Phase)

N/A 39.3 A

Amperage at 380 Volt (V) Alternating Current (AC) Voltage (3Ø Phase)

N/A 22.8 A

Amperage at 415 Volt (V) Alternating Current (AC) Voltage (3Ø Phase)

N/A 20.9 A

Amperage at 440 Volt (V) Alternating Current (AC) Voltage (3Ø Phase)

N/A 19.7 A

Amperage at 480 Volt (V) Alternating Current (AC) Voltage (3Ø Phase)

N/A 18.0 A

Amperage at 600 Volt (V) Alternating Current (AC) Voltage (3Ø Phase)

N/A 14.4 A

Dimensions

Height

N/A 34 in

Length

N/A 30 in

Width

N/A 26 in

Plumbing Connection Sizes

Water Inlet

N/A Standard Hose Adapter (Female)

Steam Outlet

N/A Sanitary Fitting for Accessory Connection

Safety Valve

N/A 3/4 in. National Pipe Thread (NPT) (Female) - Safety Valve, Brass

Drain

N/A 3/4 in. National Pipe Thread (NPT) (Female) - Ball Valve, Brass

Included Options

Single Service Transformer

N/A Supplied standard with all Swash steam generators, the Transformer steps down the primary high voltage supplied for the heaters, in order to provide 120VAC 1Ø for the controls; with the option, only the one (1) primary high voltage supply is required.

Water Feed Booster Pump

N/A Supplied standard on any steam generator with an operating pressure higher than 15 psi. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-80 psi water supply with a minimum flow rate of 2 gpm.

More Options

Spare Parts Package Includes

N/A
  • 18-Month Warranty (12-Month Standard)
  • (2) Electric Heaters and (2) Heater Gaskets
  • (2) Sight Glass Tubes and (4) Washers
  • (1) Pressure Control
  • (1) Contactor

Note

Note

N/A A Manual Low Water Reset Button is supplied standard with every steam generator, but it is disabled. If this Reset Button is required as per your local boiler codes, simply plug the two attached wires into the PC-Board terminals labeled "Reset".
  • 1 Each generator is custom built to accommodate only one (1) costumer specific high voltage supply for the heaters. 120VAC 1Ø, 50/60Hz must also be supplied for the controls by the included Single Service Transformer.
  • 2 Three Phase (3Ø) primary high voltage is standard, but steam generators with a power rating of 30 kW or lower are also available in Single Phase (1Ø) upon request.
  • 3 Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feedwater must not exceed 140ºF.
  • 4 Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feedwater must not exceed 140ºF.
  • 5 Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feedwater must not exceed 140ºF.
  • 6 Wetted Surfaces. SCH 40 Carbon steel and Brass.
  • 7 Wetted Surfaces. SCH 40 Carbon steel and Brass.