Items |
S.S. LG-10 (H) 10 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator |
S.S. LG-15 (H) 15 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator |
S.S. LG-20 (H) 20 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator |
S.S. LG-25 (H) 25 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator |
S.S. LG-30 (H) 30 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator |
|||||
Description |
N/A
Standard Features:
Recommended Options (Non-Standard)
|
|||||||||
Brands | N/A Electro-Steam™ | |||||||||
Variant | N/A High Pressure | |||||||||
Electrical Power | N/A 10 kW | N/A 15 kW | N/A 20 kW | N/A 25 kW | N/A 30 kW | |||||
Power Supply Voltage1 | N/A 208 VAC230 VAC380 VAC415 VAC440 VAC480 VAC600 VAC | |||||||||
Phase2 | N/A 3 | |||||||||
Frequency | N/A 50 Hz60 Hz | |||||||||
Boiler Horse Power | N/A 1 bhp | N/A 1.5 bhp | N/A 2 bhp | N/A 2.5 bhp | N/A 3.0 bhp | |||||
Steam Capacity3 | N/A 34.5 lb/hr15.65 kg/hr | N/A 51.75 lb/hr23.47 kg/hr | N/A 69.00 lb/hr31.30 kg/hr | N/A 86.25 lb/hr39.12 kg/hr | N/A 103.5 lb/hr46.95 kg/hr | |||||
Water Consumption | N/A 4.13 gal/hr15.65 L/hr | N/A 6.20 gal/hr23.47 L/hr | N/A 8.27 gal/hr31.30 L/hr | N/A 10.34 gal/hr39.12 L/hr | N/A 12.4 gal/hr46.95 L/hr | |||||
Gross British Thermal Units (BTU) Output | N/A 33,475 Btu/hr | N/A 50,213 Btu/hr | N/A 66,951 Btu/hr | N/A 83,688 Btu/hr | N/A 100,426 Btu/hr | |||||
Maximum Boiler Pressure | N/A 100 psi | |||||||||
Operating Pressure | N/A 0 to 80 psi | |||||||||
Note for Operating Pressure | N/A Factory Set at 80 psi | |||||||||
Maximum Boiler Capacity | N/A 6 gal | |||||||||
Boiler Fill Capacity | N/A 4.2 gal | |||||||||
Boiler Material 4 | N/A 316L Stainless Steel | |||||||||
Cabinet Material | N/A 304 Stainless Steel | |||||||||
Plumbing Material | N/A 316L Stainless Steel (Schedule 40) | |||||||||
Industry Standards | N/A American Society of Mechanical Engineers (ASME) - Boiler and Pressure Vessel Code American Society of Mechanical Engineers (ASME) - CSD-1 Canadian Underwriters Laboratories (cUL) Underwriters Laboratories (UL) | |||||||||
Amperage at 208 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 27.70 A | N/A 41.60 A | N/A 55.40 A | N/A 69.40 A | N/A 83.30 A | |||||
Amperage at 240 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 26.20 A | N/A 39.30 A | N/A 52.30 A | N/A 65.50 A | N/A 78.60 A | |||||
Amperage at 380 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 15.20 A | N/A 22.80 A | N/A 30.30 A | N/A 38.00 A | N/A 45.60 A | |||||
Amperage at 415 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 13.90 A | N/A 20.90 A | N/A 27.80 A | N/A 34.80 A | N/A 41.70 A | |||||
Amperage at 440 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 13.10 A | N/A 19.70 A | N/A 26.20 A | N/A 32.80 A | N/A 39.40 A | |||||
Amperage at 480 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 12.00 A | N/A 18.00 A | N/A 24.00 A | N/A 30.10 A | N/A 36.10 A | |||||
Amperage at 600 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 9.60 A | N/A 14.40 A | N/A 19.20 A | N/A 24.00 A | N/A 28.90 A | |||||
Length | N/A 27 in | |||||||||
Width (No Options Included) | N/A 21 in | |||||||||
Width (Single Service Transformer Option Included) | N/A 26 in | |||||||||
Height | N/A 23 in | |||||||||
Total Length | N/A 49 in | |||||||||
Total Width | N/A 42 in | |||||||||
Total Height | N/A 31 in | |||||||||
Water Inlet | N/A 3/8" National Pipe Thread (NPT) (Female) - Water Solenoid, 316L Stainless Steel (SS) | |||||||||
Steam Outlet | N/A 1/2" National Pipe Thread (NPT) (Female) - Ball Valve, 316L SS | |||||||||
Safety Valve | N/A 3/4" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces), Brass Body | |||||||||
Drain | N/A 3/4" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS) | |||||||||
Spare Parts Package Includes |
N/A
|
|||||||||
Single Service Transformer | N/A Supplied standard with all portable steam generators, the Single Service Transformer steps down the primary high voltage to provide 120 VAC Single Phase (1Ø) to the controls; with this option, only the one (1) primary high voltage supply is required. | |||||||||
Manual Low Water Reset5 | N/A Manual Low Water Reset trips if the electric heaters shut-off because of a low water condition. Reset must be manually pressed to resume steam production. | |||||||||
Portable Mounting Includes |
N/A
|
|||||||||
Water Feed Booster Pump | N/A Supplied standard on any steam generator with an operating pressure higher than 15 psi. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-80 psi water supply with a minimum flow rate of 2 gpm. | |||||||||
|