Items |
S.S. LB-100 (L) 100 Kilowatt (kW) Electrical Power Rating Low Pressure Electric Steam Generator |
S.S. LB-120 (L) 120 Kilowatt (kW) Electrical Power Rating Low Pressure Electric Steam Generator |
S.S. LB-150 (L) 150 Kilowatt (kW) Electrical Power Rating Low Pressure Electric Steam Generator |
S.S. LB-180 (L) 180 Kilowatt (kW) Electrical Power Rating Low Pressure Electric Steam Generator |
S.S. LB-240 (L) 240 Kilowatt (kW) Electrical Power Rating Low Pressure Electric Steam Generator |
|||||
Description |
N/A
Standard Features:
Recommended Options (Non-Standard)
|
N/A
Standard Features:
Recommended Options (Non-Standard)
|
N/A
Standard Features:
Recommended Options (Non-Standard)
|
N/A
Standard Features:
Recommended Options (Non-Standard)
|
N/A
Standard Features:
Recommended Options (Non-Standard)
|
|||||
Brands | N/A Electro-Steam™ | |||||||||
Variant | N/A Low Pressure | |||||||||
Electrical Power | N/A 100 kW | N/A 120 kW | N/A 150 kW | N/A 180 kW | N/A 240 kW | |||||
Power Supply Voltage1 | N/A 208 VAC230 VAC380 VAC415 VAC440 VAC480 VAC600 VAC | N/A 208 VAC230 VAC380 VAC415 VAC440 VAC480 VAC600 VAC | N/A 208 VAC230 VAC380 VAC415 VAC440 VAC480 VAC600 VAC | N/A 208 VAC230 VAC380 VAC415 VAC440 VAC480 VAC600 VAC | N/A 380 VAC415 VAC440 VAC480 VAC600 VAC | |||||
Phase2 | N/A 3 | |||||||||
Frequency | N/A 50 Hz60 Hz | |||||||||
Boiler Horse Power | N/A 10 bhp | N/A 12 bhp | N/A 15 bhp | N/A 18 bhp | N/A 24 bhp | |||||
Steam Capacity3 | N/A 345 lb/hr156.49 kg/hr | N/A 414 lb/hr187.79 kg/hr | N/A 517.5 lb/hr234.73 kg/hr | N/A 621 lb/hr281.68 kg/hr | N/A 828.0 lb/hr375.57 kg/hr | |||||
Water Consumption | N/A 41.34 gal/hr156.49 L/hr | N/A 49.61 gal/hr187.79 L/hr | N/A 62.01 gal/hr234.73 L/hr | N/A 74.41 gal/hr281.68 L/hr | N/A 99.22 gal/hr375.57 L/hr | |||||
Note for Water Consumption | N/A | |||||||||
Gross British Thermal Units (BTU) Output | N/A 334754 Btu/hr | N/A 401704 Btu/hr | N/A 502130 Btu/hr | N/A 602556 Btu/hr | N/A 803409 Btu/hr | |||||
Maximum Boiler Pressure | N/A 15 psi | |||||||||
Operating Pressure | N/A 0 to 11 psi | |||||||||
Note for Operating Pressure | N/A Factory Set at 11 psi | |||||||||
Maximum Boiler Capacity | N/A 26.5 gal | |||||||||
Boiler Fill Capacity | N/A 22.0 gal | |||||||||
Boiler Material 4 | N/A 316L Stainless Steel | |||||||||
Cabinet Material | N/A 304 Stainless Steel | |||||||||
Plumbing Material | N/A 316L Stainless Steel (Schedule 40) | |||||||||
Industry Standards | N/A American Society of Mechanical Engineers (ASME) - Boiler and Pressure Vessel Code American Society of Mechanical Engineers (ASME) - CSD-1 Canadian Underwriters Laboratories (cUL) Underwriters Laboratories (UL) | |||||||||
Amperage at 208 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 277.6 A (138.8 A per Box) | N/A 333.1 A (166.5 A per Box) | N/A 416.4 A (208.2 A per Box) | N/A 499.6 A (249.8 A per Box) | N/A | |||||
Amperage at 240 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 261.9 A (131 A per Box) | N/A 314.3 A (157.2 A per Box) | N/A 392.9 A (196.5 A per Box) | N/A 471.5 A (235.7 A per Box) | N/A | |||||
Amperage at 380 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 151.9 A (76 A per Box) | N/A 182.3 A (91.2 A per Box) | N/A 227.9 A (114 A per Box) | N/A 273.5 A (136.7 A per Box) | N/A 364.6 A (182.3 A per Box) | |||||
Amperage at 415 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 139.1 A (69.6 A per Box) | N/A 166.9 A (83.5 A per Box) | N/A 208.7 A (104.3 A per Box) | N/A 250.4 A (125.2 A per Box) | N/A 333.9 A (166.9 A per Box) | |||||
Amperage at 440 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 131.2 A (65.6 A per Box) | N/A 157.5 A (78.7 A per Box) | N/A 196.8 A (98.4 A per Box) | N/A 236.2 A (118.1 A per Box) | N/A 314.9 A (157.5 A per Box) | |||||
Amperage at 480 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 120.3 A (60.1 A per Box) | N/A 144.3 A (72.2 A per Box) | N/A 180.4 A (90.2 A per Box) | N/A 216.5 A (108.3 A per Box) | N/A 288.7 A (144.3 A per Box) | |||||
Amperage at 600 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 96.2 A (48.1 A per Box) | N/A 115.5 A (57.7 A per Box) | N/A 144.3 A (72.2 A per Box) | N/A 173.2 A (86.6 A per Box) | N/A 230.9 A (115.5 A per Box) | |||||
Length | N/A 51 in | |||||||||
Width | N/A 30 in | |||||||||
Height | N/A 37 in | |||||||||
Total Length | N/A 120 in | |||||||||
Total Width | N/A 60 in | |||||||||
Total Height | N/A 45 in | |||||||||
Water Inlet | N/A 1/2" National Pipe Thread (NPT) (Female) - Street Elbow, 316L Stainless Steel (SS) | |||||||||
Steam Outlet | N/A 1" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS) | |||||||||
Safety Valve | N/A 2" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces) , Brass Body | |||||||||
Drain | N/A 1" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS) | |||||||||
Spare Parts Package Includes |
N/A
|
|||||||||
Single Service Transformer | N/A Supplied standard with all portable steam generators, the Single Service Transformer steps down the primary high voltage to provide 120 VAC Single Phase (1Ø) to the controls; with this option, only the one (1) primary high voltage supply is required. | |||||||||
Manual Low Water Reset5 | N/A Manual Low Water Reset trips if the electric heaters shut-off because of a low water condition. Reset must be manually pressed to resume steam production. | |||||||||
Portable Mounting Includes |
N/A
|
|||||||||
Water Feed Booster Pump | N/A The minimum requirement for your water pressure is the operating pressure +25 psi; if your water pressure is below this requirement, this option must be added. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm. | |||||||||
|