Standard Features:
Recommended Options (Non-Standard):
Items |
DS-150 (H) 150 Kilowatt (kW) Double Stack High Pressure Electric Steam Generator |
DS-200 (H) 200 Kilowatt (kW) Double Stack High Pressure Electric Steam Generator |
DS-240 (H) 240 Kilowatt (kW) Double Stack High Pressure Electric Steam Generator |
DS-300 (H) 300 Kilowatt (kW) Double Stack High Pressure Electric Steam Generator |
DS-360 (H) 360 Kilowatt (kW) Double Stack High Pressure Electric Steam Generator |
|||||
Description |
N/A
Standard Features:
|
|||||||||
Brands | N/A Electro-Steam™ | |||||||||
Electrical Power | N/A 150 kW (75 kW per Box) (2 Boxes) | N/A 200 kW (50 kW per Box) (4 Boxes) | N/A 240 kW (60 kW per Box) (4 Boxes) | N/A 300 kW (75 kW per Box) (4 Boxes) | N/A 360 kW (90 kW per Box) (4 Boxes) | |||||
Alternating Current (AC) Voltage1 | N/A 208 V230 V360 V400 V480 V600 V | |||||||||
Phase | N/A 3 | |||||||||
Frequency | N/A 50 Hz60 Hz | |||||||||
Boiler Horse Power | N/A 15 bhp (7.5 bhp per Boiler) | N/A 20 bhp (10 bhp per Boiler) | N/A 24 bhp (12 bhp per Boiler) | N/A 30 bhp (15 bhp per Boiler) | N/A 36 bhp (18 bhp per Boiler) | |||||
Steam Capacity2 | N/A 517.5 lb/hr234.0 kg/hr | N/A 690.0 lb/hr312.0 kg/hr | N/A 828.0 lb/hr374.4 kg/hr | N/A 1,035 lb/hr468.0 kg/hr | N/A 1,242 lb/hr561.6 kg/hr | |||||
Average Water Consumption3 | N/A 62.01 gal/hr234.0 L/hr | N/A 82.68 gal/hr312.0 L/hr | N/A 99.22 gal/hr374.4 L/hr | N/A 124.0 gal/hr468.0 L/hr | N/A 148.8 gal/hr561.6 L/hr | |||||
Gross British Thermal Units (BTU) Output4 | N/A 502,080 Btu/hr | N/A 669,440 Btu/hr | N/A 803,328 Btu/hr | N/A 1,004,160 Btu/hr | N/A 1,204,992 Btu/hr | |||||
Maximum Boiler Pressure | N/A 100 psi | |||||||||
Operating Pressure | N/A 0 to 80 psi | |||||||||
Note for Operating Pressure | N/A Factory Set at 80 psi | |||||||||
Maximum Boiler Capacity | N/A 53 gal | |||||||||
Note for Maximum Boiler Capacity | N/A 26.5 Gallons per Boiler | |||||||||
Boiler Fill Capacity | N/A 44 gal | |||||||||
Note for Boiler Fill Capacity | N/A 22.0 Gallons per Boiler | |||||||||
Boiler Material 5 | N/A Carbon Steel | |||||||||
Cabinet Material | N/A 304 Stainless Steel | |||||||||
Plumbing Material6 | N/A Brass (Schedule 40) Carbon Steel (Schedule 40) | |||||||||
Industry Standards | N/A American Society of Mechanical Engineers (ASME) - Boiler and Pressure Vessel Code American Society of Mechanical Engineers (ASME) - CSD-1 Canadian Underwriters Laboratories (cUL) Underwriters Laboratories (UL) | |||||||||
Amperage at 208 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 416.4 A (208.2 A per Box) (2 Boxes) | N/A 555.1 Amps (138.8 Amps per Box) (4 Boxes) | N/A 666.2 Amps (166.5 Amps per Box) (4 Boxes) | N/A 832.7 Amps (208.2 Amps per Box) (4 Boxes) | N/A 999.3 Amps (249.8 Amps per Box) (4 Boxes) | |||||
Amperage at 230 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 392.9 A (196.5 A per Box) (2 Boxes) | N/A 523.9 Amps (131.0 Amps per Box) (4 Boxes) | N/A 628.6 Amps (157.2 Amps per Box) (4 Boxes) | N/A 785.8 Amps (196.5 Amps per Box) (4 Boxes) | N/A 943.0 Amps (235.7 Amps per Box) (4 Boxes) | |||||
Amperage at 360 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 253.6 A (126.8 A per Box) (2 Boxes) | N/A 338.1 Amps (84.52 Amps per Box) (4 Boxes) | N/A 405.7 Amps (101.4 Amps per Box) (4 Boxes) | N/A 507.1 Amps (126.8 Amps per Box) (4 Boxes) | N/A 608.5 Amps (152.1 Amps per Box) (4 Boxes) | |||||
Amperage at 380 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A | |||||||||
Amperage at 400 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 226.5 A (113.2 A per Box) (2 Boxes) | N/A 302.0 Amps (75.49 Amps per Box) (4 Boxes) | N/A 362.3 Amps (90.59 Amps per Box) (4 Boxes) | N/A 452.9 Amps (113.2 Amps per Box) (4 Boxes) | N/A 543.5 Amps (135.9 Amps per Box) (4 Boxes) | |||||
Amperage at 415 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A | |||||||||
Amperage at 480 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 180.4 A (90.21 A per Box) (2 Boxes) | N/A 240.6 Amps (60.14 Amps per Box) (4 Boxes) | N/A 288.7 Amps (72.17 Amps per Box) (4 Boxes) | N/A 360.8 Amps (90.21 Amps per Box) (4 Boxes) | N/A 433.0 Amps (108.3 Amps per Box) (4 Boxes) | |||||
Amperage at 600 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 144.3 A (72.17 A per Box) (2 Boxes) | N/A 192.5 Amps (48.11 Amps per Box) (4 Boxes) | N/A 230.9 Amps (57.74 Amps per Box) (4 Boxes) | N/A 288.7 Amps (72.17 Amps per Box) (4 Boxes) | N/A 346.4 Amps (86.60 Amps per Box) (4 Boxes) | |||||
Length | N/A 64 in | |||||||||
Width | N/A 38 in | |||||||||
Height | N/A 63 in | |||||||||
Total Length | N/A 125 in | |||||||||
Total Width | N/A 60 in | |||||||||
Total Height | N/A 70 in | |||||||||
Water Inlet (Shared) | N/A 1/2" NPT (Female) - Y-Strainer, Brass | |||||||||
Steam Outlet (Shared) | N/A 6" Flange (150 psi, 4-Hole) - 2-1/2" pipe connection | |||||||||
Safety Valves (x2)(Separate) | N/A 1-1/4" NPT (Male) (x2) - Two Black Pipes routed to the floor; one from each Safety Valve. | |||||||||
Drain + MAFD Option (Shared) | N/A 1" NPT (Female) - Elbow, Brass | |||||||||
Steam Trap (Not Included) | N/A 3/4" NPT (Female) - Threaded connection on the bottom of the 2-1/2" shared Steam Outlet pipe. | |||||||||
Motorized Automatic Flush and Drain (MAFD) | N/A Two of these options are supplied standard in all double stack steam generators; the motorized drain valve opens for three (3) minutes during every start-up. As old water is drained out, fresh water is cycled in. This drain valve will not open if the pressure in the steam generator exceeds 5 psi. The electric heaters are locked out during flush cycle. | |||||||||
Single Service Transformer7 | N/A Two of these options are supplied standard in all double stack steam generators; the Transformer steps down the primary high voltage supplied for the heaters, in order to provide 120VAC 1Ø for the controls; with this option, only the two (2) primary high voltage supplies are required. | |||||||||
Manual Low Water Reset8 | N/A Manual Low Water Reset trips if the electric heaters shut-off because of a low water condition. Reset must be manually pressed to resume steam production. | |||||||||
Water Feed Booster Pump | N/A Two Water Feed Booster Pumps are supplied standard in all high-pressure double stack steam generators. Each Water Feed Booster Pump increases the incoming water pressure to overcome the operating pressure of each steam generator. Each Booster Pump requires a 5-150 psi water supply with a minimum flow rate of 3 gpm (At least 6 gpm is required for both) | |||||||||
Spare Parts Package Includes |
N/A
|
|||||||||
5-Micron Water Filter | N/A 2-stage, 5-micron water filter installed into incoming water line to reduce sediment, dirt, rust, chlorine, and even odor from incoming water supply. | |||||||||
|