S.S. LB 40-60 Electric Steam Generators
Process Steam Generators
Standard Features
Recommended Options (Non-Standard)
- 316L Stainless Steel on all Wetted Surfaces
- With the exception of our hawk series, all of our steam generators are built by an ASME Certificate holder in accordance with ASME BPVC Section I – Rules for Construction of Power Boilers (“ASME BPVC Section I”). They also comply with the requirements outlined in The National Board Synopsis of Boiler and Pressure Vessel Laws, Rules and Regulations (NB-370) RULES FOR CONSTRUCTION AND STAMPING section, which for many jurisdictions include but are not limited to ASME BPVC Section I, ASME CSD-1, ASME B31.1, and REGISTRATION WITH THE NATIONAL BOARD.
- High Pressure Safety Reset
- UL Listed and labeled under UL 834
- Dual Pressure Controls (UL 353)
- Low Level Cut-Off (LLCO)
- Safety Relief Valve possessing the ASME V Mark (these valves are built by a manufacturer holding a valid ASME Certificate of Authorization).
Recommended Options (Non-Standard)
- Spare Parts Package
- Single Service Transformer
Unit of Measure
Items |
/Asset/S-S--LB-40-60.jpg S.S. LB-40 (H) 40 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator |
/Asset/S-S--LB-40-60.jpg S.S. LB-50 (H) 50 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator |
/Asset/S-S--LB-40-60.jpg S.S. LB-60 (H) 60 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator |
/Asset/S-S--LB-40-60.jpg S.S. LB-40 (L) 40 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator |
/Asset/S-S--LB-40-60.jpg S.S. LB-50 (L) 50 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator |
|||||
Description |
N/A
Standard Features:
Recommended Options (Non-Standard)
|
N/A
Standard Features:
Recommended Options (Non-Standard)
|
N/A
Standard Features:
Recommended Options (Non-Standard)
|
N/A
Standard Features:
Recommended Options (Non-Standard)
|
N/A
Standard Features:
Recommended Options (Non-Standard)
|
|||||
Brands | N/A Electro-Steam™ | |||||||||
Variant | N/A High Pressure | N/A High Pressure | N/A High Pressure | N/A Low Pressure | N/A Low Pressure | |||||
Electrical Power | N/A 40 kW | N/A 50 kW | N/A 60 kW | N/A 40 kW | N/A 50 kW | |||||
Power Supply Voltage1 | N/A 208 VAC230 VAC380 VAC415 VAC440 VAC480 VAC600 VAC | |||||||||
Phase | N/A 3 | |||||||||
Note for Phase | N/A Three Phase (3Ø) primary high voltage is standard, but steam generators with a power rating of 30 kW or lower are also available in Single Phase (1Ø) upon request. | N/A Three Phase (3Ø) primary high voltage is standard, but steam generators with a power rating of 30 kW or lower are also available in Single Phase (1Ø) upon request. | N/A Three Phase (3Ø) primary high voltage is standard, but steam generators with a power rating of 30 kW or lower are also available in Single Phase (1Ø) upon request. | N/A | N/A | |||||
Frequency | N/A 50 Hz60 Hz | |||||||||
Boiler Horse Power | N/A 4.0 bhp | N/A 5.00 bhp | N/A 6.0 bhp | N/A 4.0 bhp | N/A 5.00 bhp | |||||
Steam Capacity2 | N/A 138.0 lb/hr62.6 kg/hr | N/A 172.50 lb/hr78.24 kg/hr | N/A 207.0 lb/hr93.89 kg/hr | N/A 138.0 lb/hr62.6 kg/hr | N/A 172.50 lb/hr78.24 kg/hr | |||||
Water Consumption | N/A 16.54 gal/hr62.6 L/hr | N/A 20.67 gal/hr78.24 L/hr | N/A 24.8 gal/hr93.89 L/hr | N/A 16.54 gal/hr62.6 L/hr | N/A 20.67 gal/hr78.24 L/hr | |||||
Note for Water Consumption | N/A | N/A | N/A | N/A Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feed-water must not exceed 140ºF. | N/A Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feed-water must not exceed 140ºF. | |||||
Gross British Thermal Units (BTU) Output | N/A 133,901 Btu/hr | N/A 167377 Btu/hr | N/A 200,852 Btu/hr | N/A 133,901 Btu/hr | N/A 167377 Btu/hr | |||||
Maximum Boiler Pressure | N/A 100 psi | N/A 100 psi | N/A 100 psi | N/A 15 psi | N/A 15 psi | |||||
Operating Pressure | N/A 0 to 80 psi | N/A 0 to 80 psi | N/A 0 to 80 psi | N/A 0 to 11 psi | N/A 0 to 11 psi | |||||
Note for Operating Pressure | N/A Factory Set at 80 psi | N/A Factory Set at 80 psi | N/A Factory Set at 80 psi | N/A | N/A | |||||
Maximum Boiler Capacity | N/A 15 gal | |||||||||
Boiler Fill Capacity | N/A 11 gal | |||||||||
Boiler Material 3 | N/A 316L Stainless Steel | |||||||||
Cabinet Material | N/A 304 Stainless Steel | |||||||||
Plumbing Material | N/A 316L Stainless Steel (Schedule 40) | |||||||||
Industry Standards | N/A American Society of Mechanical Engineers (ASME) - Boiler and Pressure Vessel Code American Society of Mechanical Engineers (ASME) - CSD-1 Canadian Underwriters Laboratories (cUL) Underwriters Laboratories (UL) | |||||||||
Amperage at 208 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 111.00 A | N/A 138.80 A | N/A 166.50 A | N/A 111.00 A | N/A 138.80 A | |||||
Amperage at 208 VAC (3Ø Phase) Per Box | N/A 104.80 A | N/A 131.00 A | N/A 157.20 A | N/A | N/A | |||||
Amperage at 240 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 60.80 A | N/A 76.00 A | N/A 91.20 A | N/A 104.80 A | N/A 131.00 A | |||||
Amperage at 240 VAC (3Ø Phase) Per Box | N/A 55.60 A | N/A 69.60 A | N/A 83.50 A | N/A | N/A | |||||
Amperage at 380 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 52.50 A | N/A 65.60 A | N/A 78.70 A | N/A 60.80 A | N/A 76.00 A | |||||
Amperage at 380 VAC (3Ø Phase) Per Box | N/A 48.10 A | N/A 60.10 A | N/A 72.20 A | N/A | N/A | |||||
Amperage at 415 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A 38.50 A | N/A 48.10 A | N/A 57.70 A | N/A 55.60 A | N/A 69.60 A | |||||
Amperage at 440 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A | N/A | N/A 78.70 A | N/A 52.50 A | N/A 65.60 A | |||||
Amperage at 480 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A | N/A | N/A | N/A 48.10 A | N/A 60.10 A | |||||
Amperage at 600 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) | N/A | N/A | N/A | N/A 38.50 A | N/A 48.10 A | |||||
Length | N/A 52 in | |||||||||
Width | N/A 26 in | |||||||||
Height | N/A 36 in | |||||||||
Total Length | N/A 96 in | |||||||||
Total Width | N/A 58 in | |||||||||
Total Height | N/A 45 in | |||||||||
Water Inlet | N/A 1/2" National Pipe Thread (NPT) (Female) - Street Elbow, 316L Stainless Steel (SS) | |||||||||
Steam Outlet | N/A 3/4" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS) | N/A 3/4" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS) | N/A 3/4" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS) | N/A 3/4" National Pipe Thread (NPT) (Female) - Ball Valve, 316L SS | N/A 3/4" National Pipe Thread (NPT) (Female) - Ball Valve, 316L SS | |||||
Safety Valve | N/A 3/4" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces) , Brass Body | N/A 3/4" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces) , Brass Body | N/A 3/4" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces) , Brass Body | N/A 3/4" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces), Brass Body. | N/A 3/4" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces), Brass Body. | |||||
Drain | N/A 1" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS) | |||||||||
Spare Parts Package Includes |
N/A
|
|||||||||
Single Service Transformer | N/A Supplied standard with all portable steam generators, the Single Service Transformer steps down the primary high voltage to provide 120 VAC Single Phase (1Ø) to the controls; with this option, only the one (1) primary high voltage supply is required. | N/A Supplied standard with all portable steam generators, the Single Service Transformer steps down the primary high voltage to provide 120 VAC Single Phase (1Ø) to the controls; with this option, only the one (1) primary high voltage supply is required. | N/A Supplied standard with all portable steam generators, the Single Service Transformer steps down the primary high voltage to provide 120 VAC Single Phase (1Ø) to the controls; with this option, only the one (1) primary high voltage supply is required. | N/A Supplied standard with all portable steam generators, the Transformer steps down the primary high voltage supplied for the heaters, in order to provide 120 VAC1Ø for the controls; with the option, only the one (1) primary high voltage supply is required. | N/A Supplied standard with all portable steam generators, the Transformer steps down the primary high voltage supplied for the heaters, in order to provide 120 VAC1Ø for the controls; with the option, only the one (1) primary high voltage supply is required. | |||||
Manual Low Water Reset4 | N/A Manual Low Water Reset trips if the electric heaters shut-off because of a low water condition. Reset must be manually pressed to resume steam production. | |||||||||
Portable Mounting Includes |
N/A
|
|||||||||
Water Feed Booster Pump | N/A Supplied standard on any steam generator with an operating pressure higher than 15 psi. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm. | N/A Supplied standard on any steam generator with an operating pressure higher than 15 psi. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm. | N/A Supplied standard on any steam generator with an operating pressure higher than 15 psi. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm. | N/A The minimum requirement for your water pressure is the operating pressure +25 psi; if your water pressure is below this requirement, this option must be added. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm. | N/A The minimum requirement for your water pressure is the operating pressure +25 psi; if your water pressure is below this requirement, this option must be added. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm. | |||||
|